Availability: | |
---|---|
Quantity: | |
Q05.1
Feature:
Blow-out proof stem adds safety and reliability to the full extent.
Thickened stem packing;V-shaped stacking desin;Adjustable self-compensating gland.
Anti-static stems are also available for specific working conditions.
3A/ISO sanitary clamp.Structure is reinforced.
No residue design.
The fluid-contacting surface is self-draining and sanitary
Equipped with a dust cap(with a handle).After feeding is completed,close the dust cap immediately to prevent any foreign matter falling into the reactor.
A manual turbine is available ,significantly decreasing the operating torque.
Equipped with a explosion-proof transponder.According to on-site environment,explosion suppression type or intrinsically safe explosion-proof type can be wisely provided.
All sealing materials contacting with fluids are reinforced PTFE,in accordance with FDA177.1550 and GMP standards
Support CIP(clean-in-place) and SIP(Sterilization-in-place).
Technical Parameters: | |
Actuation | turbine stem,aluminum pneumatic actuator(single/double acting),electric actuator |
Size | DN80-DN300 |
Body | Feeding valve body |
Fluid-Contacting Surface | SS/HC/Ti |
Non-Fluid-Contacting Surface | SS |
Connection | Flanged+weld |
Operation Pressure | DN80-DN300 PN16bar-PN63bar |
Operation Temperature | Dependent on seal materials |
Fluid-contacting surface roughness:Ra≤0.6μm≤0.25μm | |
External surface roughness:Ra≤0.8μm and ≤0.4μm |
Feature:
Blow-out proof stem adds safety and reliability to the full extent.
Thickened stem packing;V-shaped stacking desin;Adjustable self-compensating gland.
Anti-static stems are also available for specific working conditions.
3A/ISO sanitary clamp.Structure is reinforced.
No residue design.
The fluid-contacting surface is self-draining and sanitary
Equipped with a dust cap(with a handle).After feeding is completed,close the dust cap immediately to prevent any foreign matter falling into the reactor.
A manual turbine is available ,significantly decreasing the operating torque.
Equipped with a explosion-proof transponder.According to on-site environment,explosion suppression type or intrinsically safe explosion-proof type can be wisely provided.
All sealing materials contacting with fluids are reinforced PTFE,in accordance with FDA177.1550 and GMP standards
Support CIP(clean-in-place) and SIP(Sterilization-in-place).
Technical Parameters: | |
Actuation | turbine stem,aluminum pneumatic actuator(single/double acting),electric actuator |
Size | DN80-DN300 |
Body | Feeding valve body |
Fluid-Contacting Surface | SS/HC/Ti |
Non-Fluid-Contacting Surface | SS |
Connection | Flanged+weld |
Operation Pressure | DN80-DN300 PN16bar-PN63bar |
Operation Temperature | Dependent on seal materials |
Fluid-contacting surface roughness:Ra≤0.6μm≤0.25μm | |
External surface roughness:Ra≤0.8μm and ≤0.4μm |
Norminal Diameter | Norminal Pressure PN10 | Norminal Pressure PN16 | L | H | E | d | K*D | ||||||
A | B | N-φC | A | B | N-φC | DIN1850 | ISO | 3A/BPE | |||||
DN80 | / | / | / | 200 | 160 | 8-18 | 168 | 360 | 132 | 80 | 106*81 | 106*85 | 106*72.9 |
DN100 | / | / | / | 220 | 180 | 8-18 | 195 | 374 | 132 | 100 | 119*100 | 119*97.4 | 119*97.4 |
DN150*100*150 | / | / | / | 220 | 180 | 8-18 | 186 | 331 | 132 | 100 | 183*150 | 183*163 | 166.8*146.8 |
DN125 | / | / | / | 250 | 210 | 8-18 | 220 | 393 | 132 | 125 | 155*125 | 155*123 | / |
DN150*125*150 | / | / | / | 250 | 210 | 8-18 | 220 | 393 | 132 | 125 | 183*150 | 166.8*146.8 | 166.8*146.8 |
DN150 | / | / | / | 285 | 240 | 8-22 | 254 | 426 | 175 | 150 | 183*150 | 166.8*146.8 | 166.8*146.8 |
DN200*150*150 | 340 | 295 | 8-22 | 340 | 295 | 12-22 | 254 | ||||||
DN250*150*150 | 395 | 350 | 12-22 | 405 | 355 | 12-26 | 254 | ||||||
DN300*150*150 | 445 | 400 | 12-22 | 460 | 410 | 12-26 | 254 | ||||||
DN200*150*200 | 340 | 295 | 8-22 | 340 | 295 | 12-22 | 254 | 426 | 175 | 150 | 233.5*200 | 233.5*213.8 | 233.5*213.8 |
DN250*150*200 | 395 | 350 | 12-22 | 405 | 355 | 12-26 | 254 | ||||||
DN300*150*200 | 445 | 400 | 12-22 | 460 | 410 | 12-26 | 254 | ||||||
DN200 | 340 | 295 | 8-22 | 340 | 295 | 12-22 | 330 | 472 | 175 | 200 | |||
DN250*200*200 | 395 | 350 | 12-22 | 405 | 355 | 12-26 | 312 | ||||||
DN300*200*200 | 445 | 400 | 12-22 | 460 | 410 | 12-26 | 312 |
Norminal Diameter | Norminal Pressure PN10 | Norminal Pressure PN16 | L | H | E | d | K*D | ||||||
A | B | N-φC | A | B | N-φC | DIN1850 | ISO | 3A/BPE | |||||
DN80 | / | / | / | 200 | 160 | 8-18 | 168 | 360 | 132 | 80 | 106*81 | 106*85 | 106*72.9 |
DN100 | / | / | / | 220 | 180 | 8-18 | 195 | 374 | 132 | 100 | 119*100 | 119*97.4 | 119*97.4 |
DN150*100*150 | / | / | / | 220 | 180 | 8-18 | 186 | 331 | 132 | 100 | 183*150 | 183*163 | 166.8*146.8 |
DN125 | / | / | / | 250 | 210 | 8-18 | 220 | 393 | 132 | 125 | 155*125 | 155*123 | / |
DN150*125*150 | / | / | / | 250 | 210 | 8-18 | 220 | 393 | 132 | 125 | 183*150 | 166.8*146.8 | 166.8*146.8 |
DN150 | / | / | / | 285 | 240 | 8-22 | 254 | 426 | 175 | 150 | 183*150 | 166.8*146.8 | 166.8*146.8 |
DN200*150*150 | 340 | 295 | 8-22 | 340 | 295 | 12-22 | 254 | ||||||
DN250*150*150 | 395 | 350 | 12-22 | 405 | 355 | 12-26 | 254 | ||||||
DN300*150*150 | 445 | 400 | 12-22 | 460 | 410 | 12-26 | 254 | ||||||
DN200*150*200 | 340 | 295 | 8-22 | 340 | 295 | 12-22 | 254 | 426 | 175 | 150 | 233.5*200 | 233.5*213.8 | 233.5*213.8 |
DN250*150*200 | 395 | 350 | 12-22 | 405 | 355 | 12-26 | 254 | ||||||
DN300*150*200 | 445 | 400 | 12-22 | 460 | 410 | 12-26 | 254 | ||||||
DN200 | 340 | 295 | 8-22 | 340 | 295 | 12-22 | 330 | 472 | 175 | 200 | |||
DN250*200*200 | 395 | 350 | 12-22 | 405 | 355 | 12-26 | 312 | ||||||
DN300*200*200 | 445 | 400 | 12-22 | 460 | 410 | 12-26 | 312 |